DEPENDABLE Moisture Barrier Chart 

Coverage

Vaporseal SB

Vaporseal DB

Cutdown II

New (7-day) concrete slabs

ü

ü

NO

Wood

NO

NO

ü

Cutback or other adhesive residues

NO

NO

ü

Oil contamination

ü

NO

NO

FEATURES

Vaporseal SB

Vaporseal DB

Cutdown II

Base Material

Epoxy

Epoxy

Latex

Max. Previous emission rate (ASTM # F1869)

25 lbs.

25 lbs.

15 lbs.

Surface Preparation Required:

 

 

 

Surface Contaminants

Remove All

Remove All

Some Allowed

Profile Required

CSP-2 or 3

CSP-2 or 3

No (1)

Surface Required

Open, Absorptive

Open, Absorptive

Bondable

Surface Application Condition Required

Dampen

Dampen

Dry to Slightly Damp

Adhesive Compatibility

Limited

Good

Excellent

Coats Required

1

1

2 or 3

Coverage Rate - Per Unit

160-240

168-264

360-600

(sq. ft. per gallon)

(75-115)

(70-110)

(160-350)

Work Time (70º- 73ºF)

60 minutes

DB-5: 15 minutes   DB-12: 30 minutes

20-30 Minutes

Re-Coat Time (70º- 73ºF)

12 Hours

DB-5: 4-5 Hours    DB-12: 12 Hours

2-3 Hours

Cover Time

12 Hours
(within 24)

DB-5: 4-5 Hours (within 5 days)
DB-12: 12 Hours
(within 5 days)

24 Hours or more

Warranty

10-Year Full Floor

10 Year Full Floor

Prorated 5 Year

LEED Features

 

 

 

VOC Content (g/l)

55

0

0

(1) Floor covering that creates tension on the surface, like glued down wood; require the best bond for the Cutdown CSP (Profile) of 2-3 is required.