CUTDOWN II is a two part product featuring complex cross-linked latex polymers that reduces moisture vapor transmission and odor through concrete slabs. CUTDOWN II can reduce up to 15 pounds of moisture vapor transmission (when tested according to ASTMF1869) to an acceptable level for the installation of floor covering systems OR to isolate cut-back and other adhesive residue, to allow safe installation of floor covering without fear of discoloration or bleed through.
|
|
|
| Features and Benefits |
|
| PHYSICAL CHARACTERISTICS |
Color when wet: Beige/Tan
|
Color, when dry: Orange/Brown
|
Color, when dry, with
excessive vapor transmission: Dark Brown |
|
Shelf lifeonce mixed: 24 weeks, but must be re-mixed
|
Re-Coat Time: 2-24 hours
|
Cover Time: 24-48 hours
|
Bond Strength: Direct Pull Test: 300psi
|
Coverage Rate:
|
|
8 lb. MVER
85% RH |
|
15 lb. MVER
90% RH |
First Coat:
|
|
200 sq. ft./gal
|
|
160 sq. ft./gallon
|
Second Coat:
|
|
350 sq. ft./gal
|
|
350 sq. ft./gallon
|
Third Coat:
|
|
|
|
350 sq. ft./gallon
|
A 4 gallon unit used for 8 lbs. MVER2 coatswill cover 540 square feet A 4 gallon unit used for 15 lbs. MVER3 coatswill cover 360 square feet |
| Application conditions: The area should be conditioned at 70°F or more with a maximum humidity of 60% or less for 48 hours prior to application. Concrete slab temperature should be a minimum of 55°F. Once applied, the area must be kept at 70°F and 60% RH for 72 hours. If optimum applications conditions are not maintained, CUTDOWN II may require longer drying/set-up time (several days). Freezing temperatures or excessive humidity may prevent CUTDOWN II from performing properly. |
|
| PACKAGING |
7 Gallon (26 Liter) Pail
contains 4 gallons of liquid shipped
as:
Part A: 1.8 gallonsPart B: 2.2 gallons
Shelf Life: 1 year. Do Not Freeze - Protect from heat and direct sun. Store at 45-75° F. Shelf life shortened when stored in warmer conditions to 6 months or less. |
|
 |
Reduces up to 15 lb. MVER to 3 lb. or less |
|
|
 |
Protects to 90% RH (ASTM F2170) |
|
|
 |
No VOCs |
|
|
 |
Easy to Install |
|
|
 |
Resists alkalinity |
|
|
 |
Economical Coverage |
|
|
| The DEPENDABLE DIFFERENCE |
|
|
 |
More resistant to alkalinity - protects to pH of 11 |
|
|
 |
Infiltration barrier to cutback adhesive residue over wood or concrete |
|
|
 |
Compatible, in direct bond, with most floor covering systems |
|
|
Where to use...
CUTDOWN II is used to reduce vapor and odor transmission OR to isolate cutback and other adhesive residues on suspended, on-grade and below-grade concrete slabs and wood floors. CUTDOWN II may be used in industrial facilities, office buildings, retail, institutional or residential buildings. Cutdown II is not warranted for use on residential wood floors. |
|
|
|